This lets you turn certain programmed capabilities on and off.
- Enter Manual Mode: Follow the steps in the “Entering Manual Mode” section.
- Access programming: Press LOW TEMP (∧) or DELICATES (∨) until “PrOg” appears in the Four-Digit Display, then press START (enter). “AtS” will appear.
- Press LOW TEMP (∧) or DELICATES (∨) to find “CnFg,” then press START (enter).
- Enter configuration value: The three digits of the configuration value will be displayed. The active digit will flash on and off.
- Use LOW TEMP (∧) or DELICATES (∨) to change the active digit.
- Press START (enter) to save the digit and move to the next one.
- For software versions less than S003: Valid values are 0-61.
- Software version S003 and higher:
- Values 0-63 limit the time remaining display to minutes only.
- Values 64-125 enable the minutes/seconds option for the time remaining display.
- Save changes: After entering all three digits, press START (enter) to save the configuration value.
- The next option will appear:
- Software versions less than S003: “AtS” (Automatic Top-Off) will appear.
- Software version S003 and higher: “dCyC” (Default Cycle) will appear.
- To exit programming: Ensure an option is displayed (not a value). Press and hold HIGH TEMP and MED TEMP simultaneously. The control will return to its previous mode of operation.