Mountain Electronics logo
Skip to main content
How Can We Help?

Search for answers or browse our knowledge base.

You are here:
← Back
  1. Enter Manual Mode: Follow the steps in the “Entering Manual Mode” section. 
  2. Access programming: Press LOW TEMP (∧) or DELICATES (∨) until “PrOg” appears in the Four-Digit Display, then press START (enter). “AtS” will appear. 
  3. Press LOW TEMP (∧) or DELICATES (∨) to find “2toS,” then press START (enter). 
  4. Adjust coin #2 topoff time (seconds): The current number of seconds set for the topoff time will appear in the display. 
  5. Use LOW TEMP (∧) or DELICATES (∨) to increase or decrease the number of seconds to the desired value. 
    1. Note: For active topoff, either the coin #2 topoff time in minutes or seconds (or both) must be non-zero. 
    2. Setting both to zero disables topoff, requires a full cycle purchase to add time. 
    3. The maximum total cycle time (including topoff) is 99 minutes. 
    4. The default value is 0 seconds. 
  6. Save changes: Press START (enter) when the correct number of seconds is displayed. “HI t” (High Temperature) will appear next. 
  7. To exit programming: Ensure an option is displayed (not a value). Press and hold HIGH TEMP and MED TEMP simultaneously. The control will return to its previous mode.