QUICK GUIDES

EDC Dryer Controls 120V / 24V

Changing Price (Manually)

 

PRICE CHANGE

Note: Tumbler must be in “Ready” mode. Make sure no coins have been entered, and the control is not in an active cycle.

  1. Open and close the service door.
  2. Press and hold HIGH TEMP, then press MED TEMP.
  3. SPC” will appear on display.
  4. Press and hold HIGH TEMP, then press MED TEMP.
  5. Sig” will appear on display.
  6. Press the LOW TEMP pad until “nPr” appears on display.
  7. Press START to display the current number of quarters.
  8. Press LOW TEMP (+) or NO HEAT (-) to change the number.
  9. Press START to save this number.
  10. When done, press HIGH TEMP, then press MED TEMP. Control returns to “Ready” mode.

 

For more information or to change other settings, see EDC Programming and Operating Instructions Manual (p/n M411843R2).


For more information or to change other settings, see EDC Programming and Operating Instructions Manual (p/n M411843R2).

 

 

Step Display Description Comments Value
1 “SIg” Audio Signal
2 “nPr” Normal Vend Price number of quarters to start 001 = 1 quarter
3 “SPA” Special Vend A On/Off Days of Week
4 “AnP” Special Vend A Normal Price
5 “AFP” Special Vend A NO HEAT price
6 “AnL” Special Vend A Normal Time
7 “AFL” Special Vend A NO HEAT Time
8 “ASH” Special Vend A Start Hour
9 “AEH” Special Vend A End Hour
10 “nCL” Normal Cycle Time (HIGH, MED, LOW) minutes to start at normal vend 010 = 10 min/quarter

012 = 12 min/quarter

015 = 15 min/quarter

…etc…

11 “HCL” HIGH TEMP Cool Down Time minutes 002 = 2 minutes

003 = 3 minutes

…etc…

12 “HdE” HIGH TEMP Temperature
13 “PCL” MED TEMP Cool Down Time minutes 002 = 2 minutes

003 = 3 minutes

…etc…

14 “PdE” MED TEMP Temperature
15 “LCL” LOW TEMP Cool Down Time minutes 002 = 2 minutes

003 = 3 minutes

…etc…

16 “LdE” LOW TEMP Temperature
17 “Add” Additional Time Additional minutes per quarter

Value = 128+minutes

136 = 8 min

138 = 10 min

140 = 12 min

143 = 15 min

…etc…

18 “FPr” NO HEAT Vend Price number of quarters to start 001 = 1 quarter
19 “FCL” NO HEAT Cycle Time minutes per quarter 010 = 10 min/quarter

012 = 12 min/quarter

015 = 15 min/quarter

…etc…

20 “COI” Coin Value
21 “dCS” Default Cycle Status
22 “rPF” Reset After a Power Failure
23 “CFg” Control Configuration
24 “Cln” Set Real-Time Clock (minutes)
25 “CHr” Set Real-Time Clock (hours)
26 “CdA” Set Real-Time Clock (days of week)
27 “CdE” Set Real-Time Clock (date)
28 “Con” Set Real-Time Clock (month)
29 “Cyr” Set Real-Time Clock (year)

 