QUICK GUIDES

MDC Front Load Washer Controls 802248

Changing Price

 

VEND PRICE CHANGE

Note: Washer must be in “Ready” mode. Make sure no coins have been entered, and the control is not in an active cycle.

  1. Open the service door. The coin drawer must be closed.
  2. Press and hold NORMAL/HOT, then press NORMAL/WARM.
  3. “rAPd” will appear on display.
  4. Press PERM PRESS/WARM (Ó) or the DELICATES/COLD (Ô) until “PrOg” appears.
  5. Press START.
  6. Press PERM PRESS/WARM (Ó) or the DELICATES/COLD (Ô) until “AtS” appears.
  7. Press START to display the current vend price. There are four digits in the vend price, and the active digit will flash on and off.
  8. Press PERM PRESS/WARM (+) or the DELICATES/COLD (-) to increase or decrease the value of the active digit.
  9. Press START to save this number and go to the next digit.
  10. Repeat for all four digits until the display reads “dEn1”.
  11. Press START to display coin #1 denomination. For coin machines, this value should be one quarter, or “0025”. (Card reader machines – see programming manual for setup.) There are four digits in the coin value, and the active digit will flash on and off.
  12. Press PERM PRESS/WARM (+) or the DELICATES/COLD (-) to increase or decrease the value of the active digit.
  13. Press START to save this number and go to the next digit.
  14. Repeat for all four digits until the display reads “dEn2”.
  15. To exit the programming feature, press and hold NORMAL/HOT and press NORMAL/WARM to revert to the main menu.
  16. Press and hold NORMAL/HOT, then press NORMAL/WARM to return to ready mode.

 

 

For more information or to change other settings, please refer to the whole programming manual.

For more information or to change other settings, please refer to the whole programming manual.

 

 

Step Display Description Comments Value
1 “aTs” Vend Price Four-digit Vend Price
2 “dEn1” Coin #1 Amount Coin value 0025 = 1 quarter
3 “dEn2” Coin #2 Amount
4 “PLSE” Start Pulse Value
5 “CyCL” Cycle Time 3,4,5 3= 30 Hot

28 Normal Warm

27 PP Warm

23 Cold

4= 35 Hot

33 Normal Warm

32 PP Warm

28 Cold

5= 42 Hot

40 Normal Warm

39 PP Warm

35 Cold

6 “CnFg” Configuration Display
7 “dCyC” Default Cycle hEAy = Normal/Hot

nOrL = Normal/Warm

PP = Perm Press/Warm

dEL = Delicates/Cold

 

 